Application of gaus mathematical model in determination of ground concentration and distribution of sumpor dioxide before and after desulphurisation of chimney in the thermal power plant Kostolac B
Samo za registrovane korisnike
2019
Konferencijski prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The most widespread and harmful pollutant for human health is sulphur dioxide. Coal power plants
are the main pollutants of sulphur dioxide. According to the Climate Action Network (CAN), the largest sulphur dioxide pollutant in Europe is the Kostolac B thermal power plant from Serbia, which in 2016 emitted 128,000 tonnes of SO2 into the atmosphere. For these reasons, the Power Company of Serbia completed the flue gas desulphurisation plant in Kostolac B TPP in 2017, which reduces sulphur dioxide emissions. The paper analyzes the impact of different scenarios (before and after the construction of the desulphurisation plant) of sulphur dioxide emissions from TPP Kostolac B using a Gaussian dispersion model. Ground concentrations of SO2 at different distances from the thermal power plant were calculated. Based on this, the results of the flue gas dispersion and the distribution of ground concentrations of SO2 are presented in the paper.
Ključne reči:
Kostolac thermal power plant / sulphur dioxide / Gaussian modelIzvor:
Proceedings [Elektronski izvor] / IX International Conference Industrial Engineering and Environmental Protection (IIZS 2019), Zrenjanin, 3rd-4th October 2019 ; [organizer Technical Faculty "Mihajlo Pupin", Zrenjanin]. - Zrenjanin : Technical Faculty "Mihajlo Pupin", 2019, 352-359Izdavač:
- Zrenjanin : Technical Faculty "Mihajlo Pupin"
Institucija/grupa
JakovTY - CONF AU - Jaćimovski, Stevo AU - Miladinović, Slobodan PY - 2019 UR - http://jakov.kpu.edu.rs/handle/123456789/1014 AB - The most widespread and harmful pollutant for human health is sulphur dioxide. Coal power plants are the main pollutants of sulphur dioxide. According to the Climate Action Network (CAN), the largest sulphur dioxide pollutant in Europe is the Kostolac B thermal power plant from Serbia, which in 2016 emitted 128,000 tonnes of SO2 into the atmosphere. For these reasons, the Power Company of Serbia completed the flue gas desulphurisation plant in Kostolac B TPP in 2017, which reduces sulphur dioxide emissions. The paper analyzes the impact of different scenarios (before and after the construction of the desulphurisation plant) of sulphur dioxide emissions from TPP Kostolac B using a Gaussian dispersion model. Ground concentrations of SO2 at different distances from the thermal power plant were calculated. Based on this, the results of the flue gas dispersion and the distribution of ground concentrations of SO2 are presented in the paper. PB - Zrenjanin : Technical Faculty "Mihajlo Pupin" C3 - Proceedings [Elektronski izvor] / IX International Conference Industrial Engineering and Environmental Protection (IIZS 2019), Zrenjanin, 3rd-4th October 2019 ; [organizer Technical Faculty "Mihajlo Pupin", Zrenjanin]. - Zrenjanin : Technical Faculty "Mihajlo Pupin" T1 - Application of gaus mathematical model in determination of ground concentration and distribution of sumpor dioxide before and after desulphurisation of chimney in the thermal power plant Kostolac B SP - 352 EP - 359 UR - https://hdl.handle.net/21.15107/rcub_jakov_1014 ER -
@conference{ author = "Jaćimovski, Stevo and Miladinović, Slobodan", year = "2019", abstract = "The most widespread and harmful pollutant for human health is sulphur dioxide. Coal power plants are the main pollutants of sulphur dioxide. According to the Climate Action Network (CAN), the largest sulphur dioxide pollutant in Europe is the Kostolac B thermal power plant from Serbia, which in 2016 emitted 128,000 tonnes of SO2 into the atmosphere. For these reasons, the Power Company of Serbia completed the flue gas desulphurisation plant in Kostolac B TPP in 2017, which reduces sulphur dioxide emissions. The paper analyzes the impact of different scenarios (before and after the construction of the desulphurisation plant) of sulphur dioxide emissions from TPP Kostolac B using a Gaussian dispersion model. Ground concentrations of SO2 at different distances from the thermal power plant were calculated. Based on this, the results of the flue gas dispersion and the distribution of ground concentrations of SO2 are presented in the paper.", publisher = "Zrenjanin : Technical Faculty "Mihajlo Pupin"", journal = "Proceedings [Elektronski izvor] / IX International Conference Industrial Engineering and Environmental Protection (IIZS 2019), Zrenjanin, 3rd-4th October 2019 ; [organizer Technical Faculty "Mihajlo Pupin", Zrenjanin]. - Zrenjanin : Technical Faculty "Mihajlo Pupin"", title = "Application of gaus mathematical model in determination of ground concentration and distribution of sumpor dioxide before and after desulphurisation of chimney in the thermal power plant Kostolac B", pages = "352-359", url = "https://hdl.handle.net/21.15107/rcub_jakov_1014" }
Jaćimovski, S.,& Miladinović, S.. (2019). Application of gaus mathematical model in determination of ground concentration and distribution of sumpor dioxide before and after desulphurisation of chimney in the thermal power plant Kostolac B. in Proceedings [Elektronski izvor] / IX International Conference Industrial Engineering and Environmental Protection (IIZS 2019), Zrenjanin, 3rd-4th October 2019 ; [organizer Technical Faculty "Mihajlo Pupin", Zrenjanin]. - Zrenjanin : Technical Faculty "Mihajlo Pupin" Zrenjanin : Technical Faculty "Mihajlo Pupin"., 352-359. https://hdl.handle.net/21.15107/rcub_jakov_1014
Jaćimovski S, Miladinović S. Application of gaus mathematical model in determination of ground concentration and distribution of sumpor dioxide before and after desulphurisation of chimney in the thermal power plant Kostolac B. in Proceedings [Elektronski izvor] / IX International Conference Industrial Engineering and Environmental Protection (IIZS 2019), Zrenjanin, 3rd-4th October 2019 ; [organizer Technical Faculty "Mihajlo Pupin", Zrenjanin]. - Zrenjanin : Technical Faculty "Mihajlo Pupin". 2019;:352-359. https://hdl.handle.net/21.15107/rcub_jakov_1014 .
Jaćimovski, Stevo, Miladinović, Slobodan, "Application of gaus mathematical model in determination of ground concentration and distribution of sumpor dioxide before and after desulphurisation of chimney in the thermal power plant Kostolac B" in Proceedings [Elektronski izvor] / IX International Conference Industrial Engineering and Environmental Protection (IIZS 2019), Zrenjanin, 3rd-4th October 2019 ; [organizer Technical Faculty "Mihajlo Pupin", Zrenjanin]. - Zrenjanin : Technical Faculty "Mihajlo Pupin" (2019):352-359, https://hdl.handle.net/21.15107/rcub_jakov_1014 .